OPTIMAL CONNECTIVITY offers Data Logging, PLC and Process Control solutions which allow us to automize process flows. As an example we have JUMO LOGOSCREEN 700 with the below listed features:
| Display | 5.7″ TFT color screen (640 × 480 pixels, 16-bit color depth) with resistive touchscreen |
| Inputs and outputs | Up to 18 measurement inputs (universal analog inputs); up to 3 analog outputs; up to 18 digital inputs; up to 24 individually switchable digital inputs/outputs, including up to 8 high-speed counting inputs (up to 12.5 kHz); up to 7 relay outputs (changeover contacts) |
| Inputs via interface | 120 external analog inputs and 120 external digital inputs as well as 74 external texts (64 batch texts, 10 event texts) |
| Internal channels (standard) | 30 counters/integrators, 10 group reports (min./max./average) |
| Internal channels (optional) | 20 math channels, 20 logic channels, up to 8 high-speed counter channels, ST code with 40 input and 40 output variables each |
| Recording channels | 60 analog signals, 60 digital signals, 120 alarm signals, 30 × counter channels (internal); up to 10 measuring groups |
The JUMO LOGOSCREEN 700 data recorder is characterized by an intuitive, icon-based
operation and visualization concept that makes it easy to operate.
Multiple versions of the JUMO LOGOSCREEN 700 are available for process data recording. The high level of scalability allows for flexible adaptation to various customer requirements: from the device version without measurement input (120 process values via interface) through to different device versions with up to 18 measurement inputs (universal analog inputs), 3 analog outputs, 18 digital inputs, 24 individually switchable digital inputs/outputs, and 7 relay outputs. The version with FDA-compliant data recording fulfills all requirements according to 21 CFR Part 11.
In order to display the recorded data, the JUMO LOGOSCREEN 700 features various visualizations. In addition, the user can use the setup program to create up to 10 separate process screens – with up to 100 objects per process screen – according to his individual requirements.
For batch-based processes, there are up to 5 special batch recordings available, which enable the storage of additional, batch-related information. The extra code, “structured text” allows for the creation of individual measurement and recording applications